Model | Ranges | Roller Width (mm) | |||
TSB2-1000 | 0 - 1000 g | 30, 36, 41, 50, 100 | |||
TSB2-2000 | 0-2000 g | 30, 36, 41, 50, 100 | |||
TSB2-5000 | 0-5000 g | 10, 15, 20, 30, 36, 41, 50, 100 | |||
TSB2-10K | 0-10 Kg | 10, 15, 20, 30, 36, 41, 50, 100 | |||
TSB2-20K | 0-20 Kg | 10, 15, 20, 30, 36, 41, 50, 100 | |||
TSB2-50K | 0-50 Kg | 10, 15, 20, 30, 36, 41, 50, 100 | |||
TSB2-100K | 0-100 Kg | 10, 15, 20, 30, 36, 41, 50, 100** | |||
Important for your order: Please specify model and roller width! Small dual-flanged outer guide rollers are standard. All 3 rollers can be equipped with one flange, if the material to be measured is wider than the rollers. Please request when you order. Calibration to customized material:If process material differs significantly from calibration material in diameter, rigidity or shape, special calibration using customer supplied samples is recommended. For this purpose a material sample of about 5 m should be supplied. |
Accuracy | ±1 % full scale ±1 digit other calibration material: ±3 % full scale or better |
Overload protection | 100% of tension range |
Measuring roller deflection | Max. 0.5 mm |
Measuring principle | Strain gauge bridge |
Natural frequency | Approx. 500 Hz, depending on tension range |
Output signal | 0 - 1 V DC (analog) |
Temperature drift | less than ±0.05 % fullscale/ºC |
Damping | Standard: 30 Hz (other values on request) |
Temperature range | 10 - 45 ºC |
Air humidity | 85 % RH, max. |
Power supply | +12 - 24 V DC, max. 50 mA regulated |
Output signal | Standard: 0 - 1 V DC (analog) impedance: ≥ 5 kΩ Option: 0 - 10 V DC (analog), or 4-20 mA (current) digital RS 232 |
Housing material | Aluminium |
Weight, net (gross) | E. g. model TSB2-2000-50 approx. 1000g (1400 g) |