For fleece according to DIN EN ISO 9073-2 (measuring face 25 cm²/pressure 0.1 kPa and 0.5 kPa)
For geomaterials according to DIN EN ISO 964-1 (measuring face 25 cm²/pressure 2 kPa and 20 kPa, not 200 kPa)
The D-2005 device is also available with different measurement ranges:
Ranges 0 – 10 mm, 0 – 25 mm and 0 – 50 mm
(or with the equivalents in inch, switchable).
With this instrument the most popular checking methods can be applied for textiles, felt, geomaterials, paper, floor coverings, leather, foils, rubber, plastic films etc.
This alternative to the D-2010 does not have an
illuminated, menu controlled touch-screen with its
statistics functions, instead it is equipped with a dial
gauge with seven-segment display and individual keys.
Of course, there is a data output for the digital
processing of the measurement results.
The model
D-2005 is also available with special equipment for calliper dwell time gauging range preselection.
The device can be adapted to the materials to be measured according to your requirements. Thus, the calliper surfaces, the calliper materials and the measurement
pressures fit in exactly with the guidelines of ISO, EN, DIN or also with your own test regulations.
Model | Standard | Application | Feeler dia. (mm) | Feeler area (cm²) | Pressure |
D-2005-T | DIN EN ISO 5084 | Textiles | 50.42 | 20 | 0.1 kPa and 1 kPa |
D-2005-V | DIN EN ISO 9073-2 | Standard fleece | 56.42 | 25 | 0.5 kPa |
D-2005-G | DIN EN ISO 964-1 | Geomaterials | 56.42 | 25 | 2 kPa |
D-2005-G1 | DIN EN ISO 964-1 | Geomaterials | 56.42 | 25 | 2 kPa, 20 kPa and 200 kPa |
D-2005-NW | DIN EN ISO 53855 | Non-woven textiles | 56.42 35.68 |
25 10 |
0.5 kPa, 1 kPa 5 kPa |
D-2005-P* | DIN EN ISO 53105 | Paper | 16 | 2 | 100 kPa |
D-2005-HY* | DIN EN ISO 54540 | Hygenic Paper | 56.42 | 25 | 2 kPa |
D-2005-L1 | DIN EN ISO 53326 (out of date) | Leather | 10 | 0.785 | 50 kPa |
D-2005-L2 | DIN EN ISO 2589 | Leather | 10 | 0.785 | 49.1 kPa |
D-2005-Gi* | Rubber | 35.68 | 10 | 5 kPa | |
D-2005-CF | ISO 2286-3 | Rubber- or plastics-coated fabrics | 12 | 1.13 | 2 kPa, 10 kPa and 24 kPa |
D-2005-CF1 | ISO 2286-3 | Rubber- or plastics-coated fabrics | 12 | 1.13 | 2 kPa, 5 kPa, 10 kPa and 24 kPa |
Feeler Calotte | |||||
D-2005-F* | DIN 53370 | Foils | R 30 mm | 0.5 N | |
*Model D-2005-P, D-2005-HY, D-2005-Gi and D-2005-F have an resolution of 0.001mm Individual configurations to an required standard are available upon request. |
D-2020 | D-2010 | D-2005 | D-2000 | |
---|---|---|---|---|
Touch-screen with menu control in German or English | - | - | ||
Seven-segment display | - | - | ||
Display illumination | - | - | ||
Statics display | - | - | ||
Automatic zero point control | - | - | ||
Preselection of the measurement cycles | - | - | ||
Preselection of the measuring range | optional | - | ||
Adjustable dwell time | - | - | ||
Motor-driven calliper movement | - | |||
Connection for pedal | - | |||
Manual calliper movement via a control lever | - | - | - | |
Automatic material infeed, adjustable | - | - | - | |
Digital interface | ||||
Available scale divisions | 0,001 mm, 0,01 mm | |||
Possible measuring ranges | 0 – 10 mm, 0 – 25 mm, 0 – 50 mm | |||
Length × width × height (in mm, for measuring range 0 – 10 mm) |
300 * 300 * 320 | 300 * 200 * 300 | 300 * 210 * 300 | 300 * 240 * 300 |
Weight (in kg, for measuring range 0 – 10 mm) |
31,5 | 24,0 | 23,0 | 22,5 |
Measuring Range | 0 - 10 mm, (25 mm optional, Code E) |
Resolution | 0.001 mm |
Accuracy | ±0.002 mm |
Depth of jaw | 160 mm |
Measuring system | Capazitive -> Sylvac |
Display | LCD 6 digit, 8.5 mm high |
Measuring unit | mm or inch |
Feeler shape and surface pressure | According international standards DIN, EN and ISO |
Preselection of the measuring range | Optional |
Adjustable dwell time | Optional |
Output signal | RS 232 for printer and USB for PC |
Temperature range | 10 - 45 °C |
Air humidity | Max. 85 % r.H |
Dimensions | 300 x 210 x 300 mm (LxWxH) |
Weight, net (gross) | 23 kg (26 kg) |