Display: | 7-segment LED-display 8-digit display of real value, 7.6 mm high minus sign for negative values |
Operation, keypad: | Front membrane w. short-stroke keys |
Front dimensions: | DIN housing, 72 x 72 mm |
Mounting: | Front installation |
Fastening: | Clamping frame |
Weight: | Version AC: ca. 450 g Version DC: ca. 320 g |
Type of connection: | Plug-in screw terminals Grid 5.08 mm / 3.81 mm |
Core cross-section: | Max. 1.5 mm2 |
Housing material: | Polycarbonate black, UL 94V-0 |
Membrane material: | Polyester |
Supply voltage: | Choice of two voltages via switch on device. When supplied, always higher voltage adjusted. 115 / 230 VAC ±10 % (50 / 60 Hz) 24 VDC ±10 %, 5 % residual ripple |
Power consumption: | 7 VA, 6 W |
Sensor supply: | 12...26 VDC / max. 80 mA |
Signal inputs: | Optocoupler PNP, NPN Input resistance 1.65 kOhm Control current 9...16 mA |
Input counting rate: | Max. 10 kHz |
Control inputs: | 1 control input for XP reset 1 control input for B1 reset |
Signal outputs: | Can be programmed as momentary or permanent signal Impulse time can be programmed 0.01...9.99 s, tolerance: +0,01 s |
Relay signal outputs: | 3 floating center-zero relays Internal spark suppression Max. switch. voltage 250 VAC Max. switch. power 1 A Max. switch. capacity 150 VA / 30 W |
Data storage: | > 10 years via EEPROM |
Counting mode of signal inputs A / B: | A 90° B x1 |
Ambient temperature: | 0...+50 °C |
Storage temperature: | -20...+70 °C |
Relative humidity: | Max. relative humidity 80 %, at 25 °C, non-condensing |
Protection: | Front IP 65 to DIN 40050 |
General rating: | EN 61010 Part 1 - Protection class II - Overvoltage protection categ. II - Contamination factor 2 |
Interference immunity: | EN 50082-2 |
Emitted interference: | EN 50081-1 |