Most popular IVO multifunctional counter with one preset. Can be used in a wide variety of applications. Can be programmed as batch counter, timer, time relay and many more.
If the desired model is not shown in the list of prices, price is on request
| Display: | 7-segment LED-display 5-digit display of real value, 7.6 mm high Decimal point can be programmed Suppression of leading zero |
| Operation, keypad: | Front membrane with short-stroke keys |
| Front dimensions: | DIN housing 48 x 48 mm |
| Mounting: | Front installation |
| Fastening: | Clamping frame |
| Weight: | Version AC: ca. 260 g Version DC: ca. 140 g |
| Type of connection: | Plug-in screw terminals Grid 5.08 mm |
| Core cross-section: | Max. 1.5 mm2 |
| Housing material: | Polycarbonate black, UL 94V-0 |
| Membrane material: | Polyester |
| Ambient temperature: | 0...+50 °C |
| Storage temperature: | -20...+70 °C |
| Relative humudity: | Max. rel. humidity 80 %, at 25 °C, non-condensing |
| Protection: | Front IP 65 to DIN 40050 |
| General rating: | EN 61010 Part 1 - Protection class II - Overvoltage protection categ. II - Contamination factor 2 |
| Interference immunity: | EN 50082-2 |
| Emitted interference: | EN 50081-1 |
| Supply voltage: | Choice of two voltages via switch on device. When supplied, always higher voltage adjusted. 115 ±10 % / 230 VAC +6 / -10 % (50 / 60 Hz) 24 / 48 VAC ±10 % (50 / 60 Hz) 24 VDC ±10 %, 5 % residual ripple |
| Power consumption: | 7 VA, 4.5 W |
| Sensor supply: | 12...26 VDC / 50 mA |
| Signal inputs: | Optocoupler inputs Count input A / B - control current 9...16 mA - breaking current < 0.5 mA - input resistance 1.65 kOhm Reset input - control current 5...8 mA - breaking current < 0.5 mA - input resistance 3.3 kOhm Can be coded asPNP / NPN via wirejumper to screw terminal |
| Input counting rate: | Adjustable to 15 Hz, 10 kHz via DIP |
| Signal outputs: | Can be programmed as momentary or permanent signals; Impulse time can be programmed 0.01...9.99 s, tolerance: +0.01s |
| Relay signal outputs: | 1 floating relay as changeover contact Internal spark suppression Relay programmable in inverted output logic Max. switching voltage 250 VAC/110VDC Max. switching power 1 A Max. switching capacity 150 VA/30W |
| Electronic output: | NPN switching transistor - Max. switching voltage +35 V - Max. switching power 50 mA PNP switching transistor - Max. switching voltage 12...24 VDC With AC operation, depending on load - Max. switching power 50 mA, for DC operation - Max. switching power 10 mA, for AC operation |
| Data storage: | > 10 years via EEPROM |
| Operation modes: | To be programmed as adding or subtracting via DIP-switch |
| Counting mode of signal inputs A / B: | UP / DOWN, A - B, A + B, A 90° B x1, A 90° B x2, A 90° B x4 |
| Ambient temperature: | 0...+50 °C |
| Storage temperature: | -20...+70 °C |
| Relative humudity: | Max. rel. humidity 80 %, at 25 °C, non-condensing |
| Protection: | Front IP 65 to DIN 40050 |
| General rating: | EN 61010 Part 1 - Protection class II - Overvoltage protection categ. II - Contamination factor 2 |
| Interference immunity: | EN 50082-2 |
| Emitted interference: | EN 50081-1 |